Prepare effectively for your Exin CDCS EXIN EPI Certified Data Centre Specialist certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2025, ensuring you have the most current resources to build confidence and succeed on your first attempt.

Page: 1 / 2
Total 120 questions

When shielding material reaches its saturation point, what will be the impact?

A.

The shielding material will reach its optimal shielding performance state.

B.

The shielding material will no longer be able to attenuate (reduce) additional EMF.

C.

The shielding material will increase its permeability factor.

D.

The shielding material will reach its maximum electrically charged state.

What precaution shall be taken for cabling leading into an equipment rack when a data center is in a seismic-prone area?

A.

Cables should be loosely organized to allow for movement and be latched at the connectors.

B.

Cables shall be tightly organized to the rack and trays to avoid movement.

C.

Cables can be organized in any way as it is not important.

D.

Cables should be replaced by busbar trunking.

You have three UPS systems connected in parallel. The UPS systems have an imbalance in the load sharing of approximately 20%.

What should you recommend?

A.

Review the cable lengths of each UPS to the common busbar

B.

Nothing, there is no reason for any concern

C.

Review the common mode noise levels within the computer room

D.

Review the harmonics levels within the computer room

You want to make cooling more effective by setting cold aisle temperature to 4 °C (39 °F). Is this acceptable?

A.

Yes, but only if cooling systems can maintain this continuously

B.

Yes, as long as dewpoint doesn’t go below -9 °C (16 °F)

C.

No, 4 °C (39 °F) is below the allowable ASHRAE range

D.

No, intake air must be exactly 20 °C (68 °F)

What is the floor loading requirement for a Rated-3 data center according to ANSI/TIA-942?

A.

7.2 kPa

B.

8.4 kPa

C.

12 kPa

D.

15 kPa

What is a disadvantage of hypoxic-based fire suppression?

A.

Only usable in non-occupied areas

B.

Only usable in rooms with sufficient air changes

C.

Gas containers must be close to hazard

D.

Only usable with positive pressure rooms

The noise levels in the data center are approximately 91 dB (A).

Do employers need to take precautions?

A.

No, anything less than 100 dB (A) is acceptable.

B.

There are no regulations regarding noise levels inside a building. Regulations only apply to noise pollution outside of the building.

C.

As long as the data is compliant to ISO/IEC 27001 it is acceptable.

D.

Yes, since it is mandated by regulations.

What is a significant difference between a halocarbon gas-based fire suppression system and an inert gas-based fire suppression system?

A.

Inert gas has smaller-sized gas containers than halocarbon gas.

B.

Inert gas harms the environment and halocarbon gas does not.

C.

Halocarbon gas works on the basis of heat removal and inert gas works on the basis of oxygen reduction.

D.

Halocarbon gas works on the basis of oxygen reduction and inert gas works on the basis of heat removal.

What is the advantage of using Multi-fiber Push-On (MPO) connectors?

A.

No advantage, cannot be used with OM4 fiber

B.

Allows a single connector with multiple fibers running parallel, enabling easy upgrade to 40–100 Gbit/s

C.

Made of high-quality materials, reusable without risk

D.

Very flexible, can be used for both copper and optical fiber

Can you install a raised floor tight to the perimeter of the room?

A.

Yes, but only if the data center is located in Zone 0 with no or little seismic activity

B.

Yes, a raised floor needs to be installed tight to the perimeter to prevent air leakage

C.

No, to avoid damage to the raised floor due to building and hygrothermal movement

D.

No, but this applies only to raised floors with a height of over 90 cm (3 ft)

In which stage of the data center life cycle does commissioning take place?

A.

Retire

B.

Operate/optimize

C.

Implement

D.

Design

The temperature in the computer room is increased from 18 °C (64 °F) to 27 °C (81 °F). What is the impact on the amount of gas required to suppress a fire assuming a halocarbon agent?

A.

The amount of gas required will be higher

B.

The amount of gas required will not change

C.

The amount of gas required will be less

D.

The change cannot be determined without knowing the change in humidity as well

What is a potential disadvantage of using a hypoxic-based fire suppression system as a fire extinguishing system?

A.

It can only be used in computer rooms which have sufficient air changes per hour.

B.

The gas containers need to be close to the hazard area.

C.

It can only be used in non-continuous occupied areas.

D.

It can only be used in computer rooms where you have sufficient positive pressure.

A data center requires an audit for ANSI/TIA-942 Rated-3 compliance. Will the network architecture be part of this audit?

A.

No, as concurrent maintainability only applies to electrical and mechanical

B.

No, only the type of cabling used will be audited

C.

Yes, but only if network administration does not comply with ANSI/TIA-606

D.

Yes, amongst other aspects the network architecture should be Rated-3 compliant with ANSI/TIA-942

What is the advantage or disadvantage of using MPO (Multi-fiber Push On)/pre-terminated fiber?

A.

There is no advantage, as it cannot be used with OM4 optical fiber cables.

B.

There is no advantage, as it creates additional heat load in the data center.

C.

It speeds up installation and provides an easy upgrade to transmission speeds up to 40 Gbit/s -100 Gbit/s.

D.

It is a very flexible system as it can be used for both copper cables and optical fiber cables.

You are installing new copper cabling.

What is the advantage or disadvantage of choosing pre-terminated category 6 or 6A cabling?

A.

Pre-terminated cabling is already factory tested and saves installation time.

B.

There is no advantage as most new copper cabling network designs are based on category 3 or 5E for horizontal cabling.

C.

Pre-terminated cabling has a higher fire rating.

D.

Pre-terminated cabling makes ordering of the copper cables more complex, as you need to know in advance on which side the male or female connector needs to be located.

The logical overview of the data center looks as pictured below. To what TIA-942 Rating is this design made based on electrical only?

A.

Rating-4

B.

Rating-3

C.

Rating-2

D.

Rating-1

What indicates the breaking capacity of a fuse or breaker?

A.

Mechanical strength of the casing of a fuse or breaker.

B.

The maximum voltage, in case of an electrical surge, that the fuse or breaker can handle without being destroyed or causing an electric damaging arc.

C.

The current at which the device will trip.

D.

The current that a fuse or breaker is able to interrupt without being destroyed or causing an electric damaging arc.

A data center scores Rated-3 in mechanical, Rated-4 in electrical, and Rated-2 in telecommunications. What is the overall rating?

A.

Rated-2

B.

Rated-4

C.

Rated-4 since electrical is most important

D.

Depends on architectural rating

What should be implemented when an Inergen-based fire suppression system is installed in the computer room?

A.

Drainage system under raised floor

B.

Gas tanks need to be within or close to the data center

C.

Pressure release valves in the data center

D.

Proper water leak detection system