Pre-Summer Sale Special - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmaspas7

Easiest Solution 2 Pass Your Certification Exams

H13-624_V5.5 Huawei HCIP-Storage V5.5 Free Practice Exam Questions (2026 Updated)

Prepare effectively for your Huawei H13-624_V5.5 HCIP-Storage V5.5 certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2026, ensuring you have the most current resources to build confidence and succeed on your first attempt.

Page: 1 / 2
Total 125 questions

A school customer has purchased two Huawei flash storage devices and deployed them in different equipment rooms. To ensure data and service reliability, an engineer deploys the HyperReplication (remote replication) feature on the storage devices. After a fault recovery, the engineer needs to manually synchronize data to restore the pair relationship between the primary and secondary LUNs. What is the current running status of the remote replication pair?

A.

To be recovered

B.

Synchronizing

C.

Normal

D.

Split

A financial customer has purchased two Huawei flash storage devices and installed them in two equipment rooms of a local data center to deploy HyperMetro services. During quorum server network planning, only 10GE quorum links can be used when a single quorum server is deployed. 25GE and Fibre Channel networks cannot be used.

A.

TRUE

B.

FALSE

In Huawei flash storage. If an engineer wants to remotely power on the storage system, the engineer must make an appropriate networking plan for the controller enclosures of the storage system. Which of the following statements is false about the networking principles of a storage system with multiple controller enclosures?

A.

All power cables have been connected properly to the controller enclosures.

B.

The maintenance network ports of all the controller enclosures have been connected correctly in accordance with standard networking.

C.

All scale-out cables have been connected property to the controller enclosures.

D.

The maintenance terminal has been connected to any service network port on any controller enclosure.

A bank customer purchases several Huawei flash storage devices to store upper-layer Oracle database service data. If an Oracle database fault occurs, engineers need to collect Oracle alert log files to locate the fault. Which of the following commands cannot be used to query the alert log path?

A.

ioscan -funC disk > /home/pvlinks_disk

B.

CRS_HOME/bin/diagcollection.sh

C.

show parameter background_dump_dest

D.

db2support outpath -d db_name -c

Assume a bank customer purchased several Huawei flash storage devices for deploying the document Imaging service. This service mainly involves random large I/Os, more read operations than write operations, and many metadata operations, with obvious hot and cold data characteristics.

A.

TRUE

B.

FALSE

In Huawei flash storage, an administrator is a built-in role that can manage users, upgrade the system, change the system time, power off the device, and restart the device.

A.

TRUE

B.

FALSE

A government customer has purchased several Huawei scale-out storage devices, and an engineer wants to install the distributed parallel client (DPC). When creating DPC nodes, the engineer can manually add a node by entering the service IP address of the node.

A.

TRUE

B.

FALSE

A financial customer has purchased several Huawei OceanStor Pacific 9550 storage systems. When configuring basic object services on the storage systems, an engineer discovers that the object service cannot be enabled for storage nodes. Which of the following is not a possible cause?

A.

The engineer has manually adjusted the time of the cluster nodes. As a result, the conflict handling is different.

B.

NTP synchronization is not configured for the cluster, and different NTP time sources are used.

C.

Namespaces with the same name have been created under the same account.

D.

The Network Time Protocol (NTP) clock in the storage cluster is inconsistent with the clock of the client that accesses object services.

The scale-out storage system supports cabinet-level security. That is, N data blocks and M parity blocks are stored in different cabinets. If M nodes or M disks are faulty, the system can still read and write data without service interruption or data loss. If M cabinets are faulty, services may be interrupted.

A.

TRUE

B.

FALSE

To improve service availability, a manufacturing customer has purchased multiple Huawei flash storage devices and deployed active-active and remote backup services on them. In this case, if the link bandwidth is too low or the concurrent processing capability is insufficient, the active-active service may be faulty, but the remote backup service is not affected.

A.

TRUE

B.

FALSE

Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?

A.

Use the management software provided by the HBA vendor to query and modify the number of concurrent HBAs.

B.

Upgrade the HBA driver to the latest version.

C.

Change the load balancing algorithm of the multipathing software to min-task.

D.

Change the cache prefetch policy to constant prefetch.

The service system needs to be backed up before performance optimization b performed on Huawei flash storage, and up to two optimization configurations can be changed at a time.

A.

TRUE

B.

FALSE

In Huawei container storage solution, CSI is short for Container Storage Interface. Which of the following statements is false about Huawei CSI?

A.

CSI Driver developed by Huawei is mainly used to implement the call initiated by sidecar on Huawei storage.

B.

Huawei storage and Huawei CSI driver need to communicate with each other through RESTful to provide NAS/SAN storage resources.

C.

CSI Controller runs independently on a worker node on the Pod in StatefulSet mode and is used to interact with the storage and create and delete resources on the storage side.

D.

CSI Node runs on each worker node of Kubernetes on the Pod in DaemonSet mode and can be used to mount and unmount related storage resources.

A financial customer purchases a Huawei flash storage device for subsequent service deployment. During storage configuration, an administrator finds that LUNs mapped to an application server cannot be detected on the application server. Which of the following are possible causes of this exception?

A.

The storage pool is faulty.

B.

In HP-UX, the application server does not have a LUN mapping whose host LUN ID is 0.

C.

In UNIX or Linux, a device node file is lost.

D.

The serial port connection parameters are incorrectly set.

Huawel OceanStor Pacific series storage supports the volume- or snapshot-based clone feature. Which of the following statements Is false about this feature?

A.

Small storage space occupation: A clone generated by the storage system is not a full physical data copy, which does not occupy large storage space.

B.

Quick generation: The storage system can generate a clone within several seconds to obtain the consistent copy of the source volume data.

C.

Lossless performance: Based on the ROW mechanism, the done write performance is equivalent to the source volume write performance.

D.

Cascading: Clones can be created based on clone volumes or snapshots of clone volumes in the storage system. A maximum of 64 cascading levels are supported.

An industry customer has purchased several Huawei flash storage devices for service deployment. An engineer wants to configure the HyperSnap feature on the storage devices. However, during the configuration, the engineer discovers that snapshots cannot be created for an existing protection group. The possible cause is that the storage pool where the source LUNs in the protection group reside has no available capacity.

A.

TRUE

B.

FALSE

An industry customer has purchased a Huawei OceanStor Pacific 9950 scale-out storage device for service deployment. During an inspection of the device, the location indicator of a main storage disk module is steady yellow. What is the status of the disk module?

A.

The main storage disk module is being located.

B.

The main storage disk module is running properly.

C.

The main storage disk module is powered off.

D.

The main storage disk module is faulty or about to fail.

Assume a financial customer purchases a Huawei OceanStor Pacific scale-out storage system for future service deployment. Which statement is false about software installation of the storage system?

A.

During block service installation, if management nodes are deployed where compute and storage nodes are converged, the number of vCPUs on each converged compute and storage node must be greater than or equal to 20.

B.

During block service installation, if converged deployment of storage and compute nodes is required, the difference between the disk quantities on any two nodes in the same storage pool cannot be greater than 2 or 30% of the disk quantity on the node having most disks.

C.

If wizard-based software installation is used, an engineer must manually add nodes, configure networks, and create a control cluster on DeviceManager, and then install the OceanStor Pacific series software.

D.

To install the Distributed Parallel Client (DPC), the memory required for running the DPC software on a compute node must be greater than or equal to 20 GB.

A financial customer has purchased several Huawei OceanStor Dorado series storage devices for mission-critical service deployment. SmartMigration is configured to migrate services from a source LUN to a target LUN without interrupting host services. Which of the following statements about this feature is false?

A.

The implementation of a SmartMigration task between heterogeneous storage systems depends on the LUN takeover function provided by SmartVirtualization.

B.

When configuring this feature, you must plan the capacities of the source and target LUNs. The capacity of the target LUN must be greater than or equal to that of the source LUN.

C.

When configuring this feature, you cannot use a LUN that has been mapped to an application server as the target LUN of a SmartMigration task.

D.

The higher the migration rate, the better the host service performance is. Therefore, the highest migration rate can be used when the host service load is heavy.

In Huawei all flash storage, the_____feature can automatically store data in different locations based on specified rules for intelligent data management.

Page: 1 / 2
Total 125 questions
Copyright © 2014-2026 Solution2Pass. All Rights Reserved