Halloween Sale Special - 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: stp75

Easiest Solution 2 Pass Your Certification Exams

H13-629_V3.0 Huawei HCIE-Storage V3.0 Free Practice Exam Questions (2026 Updated)

Prepare effectively for your Huawei H13-629_V3.0 HCIE-Storage V3.0 certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2026, ensuring you have the most current resources to build confidence and succeed on your first attempt.

Page: 1 / 1
Total 60 questions

During data migration using SmartMigration of Huawei flash storage, LUN information exchange changes the mapping between LUNs and data volumes. Which of the following statements about the mapping are true?

A.

After LUN information is exchanged, the host uses the source LUN ID to identify the target data volume.

B.

After the pair is split, the host I/O data is written only to the target LUN, and dual-write is not performed.

C.

Before LUN information is exchanged, the host uses the source LUN ID to identify the source LUN.

D.

During LUN information exchange, the LUN IDs remain unchanged, and the data volume IDs of the source and target LUNs are exchanged.

A bank uses DME to manage OceanStor Dorado 8000 and OceanProtect X9000. When the administrator creates a block storage service level and enables resource tuning, which of the following licenses needs to be imported on the storage device if Provisioning Type is set?

A.

SmartTier

B.

SmartCompression

C.

SmartDedupe

D.

SmartThin

When planning a disaster recovery (DR) system, DR levels need to be divided based on service continuity requirements and cost investment. Which of the following statements about DR levels are true?

A.

In service-level DR, all service links are redundant, including links between IT systems and non-IT systems such as office facilities and personnel.

B.

Application-level DR consists of building the same application systems at the DR site.

C.

In data-level DR, the remote DR center can be simply considered as a remote data backup center.

D.

In data-level DR, services are not interrupted if a disaster occurs.

Huawei ' s storage data migration system can be divided into multiple layers. Each layer corresponds to different migration solutions. Which of the following is the migration solution corresponding to the host file system layer?

A.

Migration solution based on Migration Director for Block

B.

Migration solution based on MigrationDirector for NAS Storage

C.

Migration solution based on MigrationDirector for NAS

D.

Migration solution based on MigrationDirector for SAN

In the file storage service scenario of Huawei all-flash storage, the multi-tenancy feature isolates resources among vStores. Which of the following are included in the multi-tenancy service isolation?

A.

Service access isolation

B.

Service network isolation

C.

Service data isolation

D.

Service configuration isolation

When an engineer is planning the OceanProtect Appliance network, the front-end storage network switches use M-LAG networking. Which front-end storage port mode should be used to ensure that links are not interrupted in the event of a switch port fault?

A.

Mode3

B.

Mode 4

C.

Model1

D.

Mode 2

A company has deployed multiple block service applications on a Huawei scale-out storage system. An administrator finds that these applications consume a large number of resources in a specific period of time and will affect other services if this situation occurs during working hours. The administrator configures SmartQoS to limit the resources consumed by these applications, preventing production services from being affected. In this scenario, which of the following performance indicators should the administrator limit?

A.

Latency

B.

OPS

C.

Bandwidth

D.

IOPS

A financial customer has purchased multiple Huawei flash storage devices for service deployment. Which of the following statements is false about service system I/O characteristics in financial scenarios?

A.

The OLAP database mainly involves sequential read of large I/Os. The amount of data processed per batch determines hot data areas.

B.

Backup and archiving services mainly involve sequential large I/Os. Writes are involved in backup and archiving services, and reads are involved in restoration services.

C.

Document imaging services mainly involve sequential read of large I/Os, a few metadata operations, and 90% GB-level large file write operations.

D.

The OLTP database mainly involves random small I/Os and a few sequential write I/Os. There are more reads than writes, and hot data areas are obvious.

The following figure shows the network diagram of the Huawei flash storage active-active DR solution for an enterprise. Data center A is the preferred site, and data center B is the non-preferred site. The administrator checks the storage system and finds that the HyperMetro pair is in the to-be-synchronized state, the LUNs in data center A are running services, and the LUNs in data center B stop providing services. In this scenario, the fault point is______. (Enter a number in the figure.)

A company uses Huawei all-flash storage to store service data. UltraPath is installed on all service hosts. A LUN on the storage device is mapped to multiple hosts, but certain hosts cannot access the LUN. A storage engineer disables the load balancing function of UltraPath and selects the First Input First Output (FIFO) mode to solve the problem.

A.

TRUE

B.

FALSE

The survey stage of storage project planning and design includes determining the project scope, collecting design data, understanding customer requirements and the project background, and identifying key stakeholders and business objectives.

A.

TRUE

B.

FALSE

In large-scale scenarios, multiple OceanProtect Appliances need to form a backup cluster that supports unified management and scale-out. Which of the following statements about planning and configuration are true?

A.

OceanProtect X3000 devices can only form a cluster with other OceanProtect X3000 devices.

B.

OceanProtect X3000 and OceanProtect X6000 devices can form a hybrid cluster. OceanProtect X6000 devices function as the active and standby nodes, and OceanProtect X3000 devices function as member nodes.

C.

OceanProtect X8000 and OceanProtect X6000 devices can form a hybrid cluster. OceanProtect X8000 devices function as the active and standby nodes, and OceanProtect X6000 devices function as member nodes.

D.

OceanProtect X9000 and OceanProtect X8000 devices can form a hybrid cluster. OceanProtect X9000 devices function as the active and standby nodes, and OceanProtect X8000 devices function as member nodes.

On Huawei all-flash storage, the secondary LUN of remote replication is read-only by default after remote replication is configured. When a disaster occurs, the primary site fails, and the remote replication link between the primary and secondary LUNs is disconnected. In this case, the administrator needs to manually set the read/write permissions of the secondary LUN to writable mode to implement service switchover.

A.

TRUE

B.

FALSE

The overall functional architecture of Huawei OceanStor Pacific series storage consists of the storage interface layer, service layer, engine layer, and management. Which of the following functions can be implemented at the engine layer?

A.

Tiered storage

B.

Protocol interworking

C.

Data reconstruction

D.

Service configuration

An enterprise has deployed Huawei all-flash storage systems in data centers A and B to carry service data and configured HyperMetro to ensure data reliability. In single quorum server mode, if the storage between data centers A and B becomes faulty, which of the following statements about the HyperMetro arbitration result are false?

A.

HyperMetro automatically switches to static priority mode.

B.

The LUNs in data center A are inaccessible, while the LUNs in data center B stop providing services.

C.

The running status of the HyperMetro pair changes to ' To be synchronized " .

D.

The LUNs in both data centers A and B continue providing services.

The OceanProtect Appliance supports host file backup and NAS file backup. For host file backup, you need to install the data protection client on the host and back up data in LAN-based mode. For NAS file backup, you need to install the NDMP dient on the host and back up data in LAN-free mode.

A.

TRUE

B.

FALSE

With the_________feature (for file) of Huawei hybrid flash storage, data in the primary file system is divided into hot data and cold data based on a specified policy. Hot data is stored on the local device. Cold

data is migrated to the remote devices using different protocols. (Enter a feature name.)

When an engineer delivers a Huawei flash storage system, LUNs cannot be detected on a Linux service host. Which of the following statements is false in this scenario?

A.

No multipathing software is installed on the host.

B.

The storage pool is faulty.

C.

Zones are incorrectly configured.

D.

The link is faulty.

Page: 1 / 1
Total 60 questions
Copyright © 2014-2026 Solution2Pass. All Rights Reserved