Weekend Sale - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmaspas7

Easiest Solution 2 Pass Your Certification Exams

NS0-593 Netapp NetApp Certified Support Engineer ONTAP Specialist Free Practice Exam Questions (2025 Updated)

Prepare effectively for your Netapp NS0-593 NetApp Certified Support Engineer ONTAP Specialist certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2025, ensuring you have the most current resources to build confidence and succeed on your first attempt.

Page: 1 / 1
Total 60 questions

Your customer added a new DS4246 shelf to their FAS2750 single-node system and created a new aggregate on the new shelf. Two weeks later, they log into Active IQ and discover the Medium Impact error shown below.

Shelves with both connections via the same SAS path detected

Referring to the exhibit, which statement is correct?

A.

In a FAS2750 system, the internal shelf is only seen on one path, and the external shelves are seen on two paths.

B.

The cables are cabled Incorrectly on the SAS stack.

C.

This situation is normal for a FA57750 single-node system.

D.

Active IQ Is not aware of the shelf configuration for a single-node system.

Your customer is running a NetApp AFF A800 system with NetApp ONTAP 9.8 software and states that their NS224 shelf is not showing with the correct shelf ID. You analyze the data and the shelf shows an identification of “1.SHFHUXXXXXXXXXX."

What is the cause of the reported Issue?

A.

The shelf has been power cycled.

B.

A new shelf was added to the controller.

C.

The shelf had a disk replaced too quickly.

D.

The shelf was cabled Incorrectly.

Which two automation methods does NetApp ONTAP Select support? (Choose two.)

A.

REST

B.

Anslble

C.

Docker

D.

PHP

An administrator receives the following error message:

What are two causes for this error? (Choose two.)

A.

There Is excessive SSD load causing the wear leveling to become unbalanced.

B.

A disk is falling.

C.

There is excessive SATA HDD load.

D.

An SSD disk is performing garbage collection to create a dense data layout.

You have a NetApp ONTAP cluster consisting of four NetApp FAS8200 controllers with two NetApp CN1610 cluster switches running ONIAP 9.8 software. You are receiving several alert messages stating that the cluster network has degraded. After troubleshooting, you determine that the errors are being generated from Node 2, interface e0b.

In this scenario, what should you do first to solve this problem?

A.

Replace the Twinax cable between Node 2, Interface e0b. and the NetApp CN1610 switch.

B.

Replace the motherboard on Node 2.

C.

Replace both NetApp CN1610 switches.

D.

Replace the NetApp CN1610 switch that connects to Node 2, interface e0b.

You receive the "Unable to connect to the management gateway server" error when trying to connect to a node management IP.

In this situation, how do you determine whether core dumps are generated for the mgwd user space process?

A.

Log in to the nodeshell using the node console and collect the core dumps from the nodeshell.

B.

Log in to the service processor and collect the core dumps from the service processor.

C.

Log in to the clustershell using the node console and collect the core dumps from the clustershell.

D.

Log in to the systemshell and collect core dumps from the systemshell.

A system panic due to an "L2 watchdog timeout hard reset" error occurred. You have found a FIFO message in the SP log.

Which FIFO message Is useful for Investigating this Issue?

A.

before NMI BBSP:C=00 L=00 FIFO: F3 F2 F1 F0 5 B2 0 0 0 80 20 E F E3 C0 C2 3 4 6 7 9 9 A

B.

BIOS exit BBSP:C=2F L=20 FIFO: 2 C8 C9 C4 24 4 6 18 7 8 11

C.

before Reset BBSP:C=00 L=00 FIFO:

D.

ONTAP Shutdown BBSP:C=00 L=2F FIFO:

You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and you receive an out of apace error message on your host.

What would cause this error?

A.

The maximum number of volume constituents has been reached in the ONTAP software.

B.

All constituent volumes are full.

C.

The inode limit is exceeded in the ONTAP software.

D.

The maxdirsize Is exceeded in the ONTAP software.

Your customer mentions that they have accidentally destroyed both root aggregates in their two-node cluster.

In this scenario, what are two actions that must be performed? (Choose two.)

A.

Rejoin the second node to the re-created cluster.

B.

Re-create the cluster from the local backup.

C.

Install ONTAP from a USB device.

D.

Re-create the cluster from the remote backup.

Which two statements about NetApp Cloud Volumes ONTAP licenses ate true? (Choose two.)

A.

Having an Essentials package enables you to convert to another licensing option.

B.

Capacity-based license packages support only single-node configurations.

C.

BYOL licenses are purchased directly from NetApp.

D.

AWS Marketplace contracts cannot be mixed with BYOL.

Recently, a CIFS SVM was deployed and is working. The customer wants to use the Dynamic DNS (DDNS) capability available in NetApp ONTAP to easily advertise bothdata UFs to their clients. Currently. DNS is only responding with one data LIF. DDNS is enabled on the domain controllers.

Referring to the exhibit, which two actions should be performed to enable DDNS updates to work? (Choose two.)

A.

Disable the -vserver-fqdn parameter for the SVM DDNS services.

B.

Remove the NFS protocol from the cifs_01 data LIF.

C.

Enable the -use-secure parameter for the SVM DDNS services.

D.

Enable the -is-enabled parameter for the SVM DDNS services

A customer enabled NFSv4.0 on an SVM and changed the client mount from NFSv3 to NFSv4. Afterwards, the customer found that the directory owner was changed from root to nobody.

In this scenario, which statement is true?

A.

The customer did not configure name services on the SVM.

B.

The clients must be restarted to start using NFSv4.

C.

The export policy is not configured properly.

D.

The ID mapping domains do not match between the client and server.

You recently discovered the error message shown below in your ONTAP logs.

What should be your first action to correct this Issue?

A.

Power cycle all the disk storage shelves that contain drives of the aggregate with the my_data_vol volume.

B.

Determine the root cause behind the inconsistency before attempting any recovery procedure.

C.

Use the storage takeover command on the storage controller that contains my_data_vol.

D.

Use the wafliron command against my_data_vol to solve the inconsistency on the volume.

A user mentions that their home drive, that Is an export within a volume, is no longer allowing them to save files. The drive reports that it Is full, even though It shows that minimal data is written to it.

Which statement would explain this behavior?

A.

The mount is stale and uses a cached version of the volume.

B.

Other users wrote to this user's home drive.

C.

Other files within the volume are also owned by the user, exceeding the user quota.

D.

The client system needs to remount the export to show the proper space.

You are optimizing your Cloud Volumes ONTAP. For interoperability and consolidation purposes, you need to know the storage limits.

In this scenario, which source should be reviewed?

A.

NetApp Cloud Volumes ONTAP Release Notes

B.

Hardware Universe

C.

Interoperability Matrix Tool (IMT)

D.

Cloud Central

A customer reports that some of their client computers are unable to access a FlexGroup over CIFS. This problem involves only their older Windows XP clients and some printers and scanners.

In this scenario, which statement Is correct?

A.

FlexGroup requires CIFS shares to be located in qtrees, which these clients do not support.

B.

FlexGroup requires CIFS shares to use the Continuously Available Feature, which these clients do not support.

C.

These systems use the SMQI protocol which Is an unsupported feature in FlexGroup

D.

These systems use Offloaded Data Transfer, which is an unsupported feature in FlexGroup.

A customer with an FC MetroCluster configuration that is running NetApp ONTAP 9.8 software experienced a site outage and wants to know why the MetroClusler configuration did not switch over to the other site.

What are two reasons for this problem? (Choose two.)

A.

There was a failed PSU in the switchover site.

B.

The ISLs were down between the sites.

C.

The site had unmirrored aggregates.

D.

An ISL link was not operating at 16Gbps.

Your customer has mounted an NFS SVM from a Linux client unci performance is very poor. The customer is certain that they have jumbo frames enabled. They have verified an MTU of 9000 on both the Linux client and the broadcast domain on the NetApp ONTAP 9.8 cluster.

Referring to the exhibit, which ONTAP command will help isolate a possible MTU mismatch?

A.

B.

C.

D.

Page: 1 / 1
Total 60 questions
Copyright © 2014-2025 Solution2Pass. All Rights Reserved