Month End Sale - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmaspas7

Easiest Solution 2 Pass Your Certification Exams

FBAP_002 Pure Storage FlashBlade Certified Architect Professional (FBAP_002) Exam Free Practice Exam Questions (2025 Updated)

Prepare effectively for your Pure Storage FBAP_002 Pure Storage FlashBlade Certified Architect Professional (FBAP_002) Exam certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2025, ensuring you have the most current resources to build confidence and succeed on your first attempt.

Page: 1 / 2
Total 75 questions

A customer wants to deploy AI/ML using Pure Storage AIRI reference architecture.

Which model should the architect use to meet the requirements?

A.

An architecture that is made up of 4xUCS X220 servers, 2xCisco Nexus 9000 switches, and FlashBlade single chassis

B.

An architecture that is made up of 4xDGX-1 servers, 2xArista 7060x switches, and FlashBlade single chassis ***

C.

An architecture that is made up of 4xDGX-1 servers, 2xArista 7060x switches, and FlashArray //X70

D.

An architecture that is made up of 4xDGX-1 servers, FlashBlade XFM, and FlashBlade single chassis.

What is the recommended number of power cables for a multi-chassis FlashBlade configuration with 4 chassis?

A.

16 power cables

B.

18 power cables

C.

20 power cables ***

D.

22 power cables

A high-profile trading company requires latency to be sub-millisecond for their trading algorithms to work properly. They are currently using Direct Attached Storage devices, which is cumbersome to administer. The company needs a network storage solution for which to run the application and store market data.

Why should the company use SAN as the solution?

A.

SAN has lower administrative overhead.

B.

Their network infrastructure is likely already built for SAN.

C.

A SAN can achieve the required latencies. ***

D.

The company needs a SAN to comply with rules and regulations.

Which of the following benefits does FlashBlade SafeMode offer?

A.

Protects against unauthorized eradication of snapshots ***

B.

Prevents the unauthorized deletion of snapshots.

C.

Protects snapshots from being overwritten.

D.

Eradicates deleted snapshots immediately.

A customer has 10x52TB blades for 328TB and 10GB/s for read performance. How much space will the customer have if 1 blade failure occurs?

A.

328TB

B.

241TB

C.

285TB***

D.

306TB

A company has a datacenter with a lot of electromagnetic interference. Their switches are 9m away from the FlashBlade and do NOT support speed faster than 10Gb/s.

Which cable should the architect use?

A.

Shielded ethernet cable. ***

B.

Passive Twinax cable.

C.

Fiber optic cable.

D.

Active Twinax cable.

A customer offers subscription access to E-books. The customer wants to be able to enable and disable access to the E-book efficiently.

What should the architect do?

A.

Create an NFS share that uses AD for authentication that can be disabled later.

B.

Create a presigned object URL that can be disabled with an API call. ***

C.

Create and object store with a user account and secret key that will be deleted in the future.

D.

Create and SMB share that uses AD for authentication and manually disable account at a later time.

A customer wants to use FlashBlade as storage for a business critical, high-traffic SQL server. Why will this architecture fail?

A.

The FlashBlade will share the database onto different blades. ***

B.

The inherent latency of NAS will disrupt the SQL server operations.

C.

The FlashBlade will be unable to scale large enough for a big SQL DB.

D.

The customer will NOT have the knowledge to run a SQL server on NAS. Lmao

A customer practices agile development, and they are having performance issues with builds of the most actively developed software suite as they attempt additional concurrent builds. What is causing the issue?

A.

Locking of shared library files during compilations.

B.

Latency between the compilation server and the legacy storage. ***

C.

Jumbo frames are NOT configured correctly.

D.

Legacy storage does NOT have enough uplinks.

A architect is reading a customer’s network diagram and notices that they are using a SAS-based NAS for a 12TB physical database server.

What does this assume about the customer?

A.

They are cost sensitive.

B.

They are latency sensitive

C.

They are NOT concerned with database performance. ***

D.

They prefer storage with built-in data reduction.

A retail customer is designing a new application that will train an AI algorithm with metadata from purchase transactions.

The customer has the following constraints:

-Billions of transactions per hour

-Hundreds of thousands of clients

-Easily connect and disconnect from many network locations

-Asymmetric encryption across a WAN

-Resilience to network latency

Which protocol should the architect recommend?

A.

NFS v3

B.

NFS v4.1 ***

C.

SMB

D.

S3

A customer needs to support 10 million files per folder for their AI environment.

What is their limiting factor on a traditional file system?

A.

Folders

B.

Inodes ***

C.

Threads

D.

Blocks

A customer wants to use and orchestration tool to manage the FlashBlade.

How should the customer create the API key?

A.

Go to Settings/Users

B.

Go to Storage/File Systems/Details

C.

Run ‘pureadmin’ from the command line ***

D.

Run ‘pureconfig’ from the command line

What is the maximum file size that is supported by the FlashBlade?

A.

32TiB

B.

64TiB ***

C.

70TiB

D.

84TiB

A customer has an application that stores GIS data in an S3 repo. For compliance reasons, the GIS data that existed at a previous point in time may need to be accessed.

What should the architect do?

A.

Enable object versioning ***

B.

Take periodic snapshots

C.

Replicate the older objects

D.

Back up the GIS data regularly

A customer has noticed their all-flash arrays are constantly running at or near 100% load and impacting application performance. They are running dozens of applications on the arrays and ask for help to identify some workloads that could be moved to another storage system to reduce load and improve overall performance of all applications.

Which (three) workload or data characteristics should an architect look for to identify potential candidates for migration to FlashBlade? (Choose three.)

A.

Applications requiring high throughput ***

B.

Large number of simultaneous connections

C.

Applications that can use NFS or S3 ***

D.

Highly transactional application.

E.

Low latency is critical to application performance. ***

An oil company moves geological data between their offices in Dubai and Houston for redundancy. The data is accessed via NFS mounts on a cluster of three 10GB connected Linux servers at each location.

A series of cron jobs are leveraged to replicate data from data storage pool A in Dubai to data storage B in Houston and from data storage A in Houston to data storage pool B in Dubai.

Data in storage pool A is read-write, updated by 50 cellular connected data collector running in the field, and deleted after 30 days.

Data in the storage pool B is read-only, queried by the firm’s analytics team, and copied to a cloud-based archive repository every 30 days.

The total amount of data in pool A in Dubai is 1.5PB

The total amount of data in pool B in Houston is 500TB

The data is not expected to grow in the next 12 months and is compressed by the application.

Which configuration should the architect present to meet this customer needs?

A . A Multi-Chassis FlashBlade with 52TB blades for each site focusing on simplicity.

B. A Multi-Chassis FlashBlade with 17TB blades for each site focusing on performance.

C. A Multi-Chassis FlashBlade with 52TB blades for each site and third-party replication software. ***

D. A Multi-Chassis FlashBlade with 17TB blades for each site and third-party replication software.

A customer has a 7x17TB FlashBlade and is adding a new workload to the system that will add 30TB of data with an expected compression rate of 1.5:1.

How many 17TB FlashBlade must be purchased to meet this requirement?

A.

1x17TB blade

B.

2x17TB blade *****

C.

3x17TB blade ***

D.

4x17TB blade

'The Network admins create a network setup:

What is the result if the FlashBlade is run in this configuration?

A.

The FlashBlade causes ARP storms. ***

B.

SMB clients are unable to connect.

C.

NFS clients experience higher latencies.

D.

FlashBlade will be unable to resolve internal DNS.

A customer is standing up a new 30x17TB FlashBlade system.

The customer’s environment is as follows:

1.The upstream switches are located 50 feet away

2.The upstream switches have the required number of 100Gb/s interfaces.

3.The customer is conscious about data availability.

4.The customer requires the use of 4 LAGs

What is the minimum number of cables required?

A.

4 passive QSFP + to QSFP + cables

B.

8 passive QSFP + to QSFP + cables

C.

4 active QSFP + to QSFP + cables

D.

8 active QSFP + to QSFP + cables ***

Page: 1 / 2
Total 75 questions
Copyright © 2014-2025 Solution2Pass. All Rights Reserved