Prepare effectively for your EMC DES-4421 Specialist - Implementation Engineer, PowerEdge MX Modular Exam certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2025, ensuring you have the most current resources to build confidence and succeed on your first attempt.

Page: 1 / 1
Total 54 questions

A technician has replaced an MX chassis tub. They complete the tub installation and power on the chassis. They notice that the KVM is no longer functional.

What should the technician do after confirming the KVM feature is still enabled in OME-M?

A.

Ensure all cables connecting the tub to the left ear control panel are connected properly

B.

Ensure all power supplies are connected and powered-on

C.

Ensure all cables connecting the tub to the right ear control panel are connected properly

D.

Ensure all installed Management Modules are connected to the network

Match the M840c components to the callouts shown in the exhibit.

Where is a valid storage location for extracting the full MX7000 chassis logs package?

A.

VMFS

B.

FTP

C.

CIFS

D.

CSV

What automatically opens a support case with technical support and collects the PowerEdge MX system state information that is required for troubleshooting an issue, then sends it securely to Dell EMC?

A.

OpenManage Essentials

B.

SupportAssist Collections

C.

OpenManage Enterprise

D.

SupportAssist Enterprise

The MDB chassis tub assembly vertical distribution board provides connectivity to which chassis components?

A.

Five near fan modules

B.

Four cooling fans and four fabric I/O modules

C.

Power supplies, compute sleds, Management Modules, and two fabric I/O modules

D.

Pear power supplies, compute sleds, Management Modules, and all fabric I/O modules

What is a characteristic of MX7000 networking in Full Switch Mode?

A.

Layer 2 bridging is disabled by default and interfaces must join a bridge domain (VLAN) before being able to forward frames.

B.

Networking is enabled by default and all switch-specific OS10EE capabilities are available.

C.

Networking is available on MX9116n FSE and MX7116n FEM but not on the MX5108n.

D.

Switches operate as layer 2 I/O aggregation devices and are managed through OME-M.

A technician replaces a failed Management Module in an MX7000 chassis group. After the technician leaves the site, the administrator reports that the lead chassis is no longer able to communicate with its members.

How can OME-M be used to confirm the cabling configuration?

A.

View the health status of the lead Chassis Management Module

B.

View the health status of the lead Chassis Management ports

C.

View the I/O module topology map from the lead chassis

D.

View the topology map from the Group Lead

What is a benefit of SmartFabric Services Mode?

A.

Topology validation and self-healing

B.

Load balancing for management layers

C.

Load balancing for application layers

D.

Automatic detection of packet collisions

What is the maximum possible weight of a fully populated MX7000 chassis?

A.

250 Ibs (114 kg)

B.

300 Ibs (136 kg)

C.

400 Ibs (182 kg)

D.

500 Ibs (227 kg)

At the initial release of the MX7000 for a daisy-chained configuration in a multi-chassis management group (MCM)m what is the maximum number of member chassis allowed, not counting the lead chassis?

A.

9

B.

10

C.

16

D.

20

Which controller option the mapping of an entire MX5016s to multiple compute sleds?

A.

PERC H730 only

B.

HBA330 only

C.

H745 Jumbo PERC

D.

HBA330 and PERC H730

While servicing an MX7000 chassis a system administrator logs into OME-M and receives a Chassis Mismatch error.

What should be the next step taken by the administrator?

A.

Clear the configuration

B.

Reset Peer or the Local IOM

C.

Perform firmware update

D.

Force Active/Clear configuration

Match each feature with its associated PowerEdge server management tool.

When running an Open Networking operating system, which IOM functions are provided through OME-M?

A.

Global and privileged configuration modes

B.

Power control and global configuration mode

C.

Hardware health and power control

D.

Hardware health and global configuration mode

An administrator has been tasked with specifying hardware for a deployment having the following requirements:

    4 node cluster within a single MX7000 chassis

    Each node needs a minimum of 6x 2.5” drives

    3 TB of memory and 64 physical CPU cores per node

What is the maximum hardware configuration that meets the requirements?

A.

MX740c with no storage sleds

B.

MX740c with MX5016s storage sleds

C.

MX840c with no storage sleds

D.

MX 840c with MX5016s storage sleds

Where in the OME-M Web interface can the Chassis Deployment Wizard be found?

A.

Hardware > Initial Configuration

B.

Configuration > Deploy > Chassis Deployment Wizard

C.

Home > Settings > Chassis Deployment Wizard

D.

Home > Configure > Initial Configuration

Page: 1 / 1