Pre-Summer Sale Special - Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: xmaspas7

Easiest Solution 2 Pass Your Certification Exams

H13-624_V5.5 Huawei HCIP-Storage V5.5 Free Practice Exam Questions (2026 Updated)

Prepare effectively for your Huawei H13-624_V5.5 HCIP-Storage V5.5 certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2026, ensuring you have the most current resources to build confidence and succeed on your first attempt.

Page: 2 / 2
Total 125 questions

During the use of Huawei flash storage, an engineer wants to calculate the valid write bandwidth of disks. Which of the following formulas can calculate disk valid write bandwidth?

A.

Valid read bandwidth of disks = Read bandwidth of a single disk x Number of disks x (Number of system disks / Total number of disks)

B.

Valid write bandwidth of disks = Write bandwidth of a single disk x Number of disks

C.

Valid write bandwidth of disks = Write bandwidth of a single disk x Number of disks x (Number of data disks / Total number of disks)

D.

Valid write bandwidth of disks = Bandwidth of a single port x Number of ports

An industry customer purchased several Huawei OceanStor Pacific series scale-out storage devices for service deployment, and an engineer configured the SmartMigration feature on the storage devices. Now the engineer wants to change the split mode and migration rate of a SmartMigration task due to changes in service requirements. Which of the following SmartMigration running statuses does not allow the engineer to perform the change?

A.

Interrupted

B.

Paused

C.

Faulty

D.

Migrating

Assume a scientific research Industry customer purchased several Huavvel OceanStor Pacific series scale-out storage devices for service deployment, and an engineer has configured the file service in the Distributed Parallel Client (DPC) scenario on the storage devices. To meet high performance requirements of front end services, the engineer wants to enable the CPU performance mode for the DPC node using the CU. Which of the following commands can be used to enable the CPU performance mode?

A.

cpupower frequency-info

B.

cpupower frequency-set -g performance

C.

change service ndmp_restart_servlce

D.

change pms converged_qos_policy

In Huawei backup storage OceanProtect X3000, data reduction supports fixed-length (^duplication by default, but does not support variable-length (^duplication. Therefore, fixed-length ded11plication Is mainly used in the backup field.

A.

TRUE

B.

FALSE

During routine inspection, engineers find that several faults occur on Huawei all-flash storage and need to rectify the faults. Which of the following is not a basic troubleshooting principle for storage systems?

A.

Analyze network alarms before NE alarms.

B.

Analyze general alarms before specific alarms.

C.

Analyze alarms of higher severities before those of lower severities.

D.

Analyze external factors before internal factors.

The OceanStor Pacific series storage systems support the _______ feature. This feature uses the classic token bucket algorithm to control the traffic upper limit. If local tokens are insufficient, tokens are continuously generated and added to the token bucket based on the OPS and bandwidth upper limit of the corresponding QoS control object as the rate.

In actual service scenarios, the characteristics of engineering, seismic, and geological data are similar to those of database backups. These types of data are stored in the same format but contain little duplicate data. In this case, the costs. feature of flash storage can be used to save storage space, thereby reducing investment and O & M

When delivering a flash storage project, Huawei engineers Introduced the SmartMuIti-Tenant feature of flash storage to the customer. Which of the following statements are true about SmartMulti Tenant?

A.

A super administrator can force itself, other super administrators, lightweight directory access protocol (LDAP) users, or LDAP user groups to change their passwords upon the next login.

B.

After a system is upgraded to support the SmartMulti-Tenant feature, all LUNs, file systems, and ports in the original system are allocated to the internal system vStore "System_vStore."

C.

To query system role information, the customer can run the "show role system" command.

D.

In flash storage, only a super administrator can modify vStore information, and the internal system vStore "System_vStore" cannot be modified.

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O & M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

The _____ feature provided by the OceanStor Pacific series storage system supports OPS and bandwidth upper limit control based on namespaces, accounts, and client IP addresses.

Huawei flash storage supports_____. That is, the existing storage system can be used to meet customers' Increasing requirements by continuously adding storage components.

A financial customer purchased an OceanStor Dorado 18000 storage system for basic service deployment. During management, an engineer discovered that the running status of an iSCSI port on DeviceManager was "Link down". After checking the indicator in the equipment room, the engineer discovered that the link indicator of the iSCSI front-end port was steady red. Which of the following are not the possible causes of the exception?

A.

The optical module type is incompatible with the host port.

B.

The IP address of the iSCSI front-end port is incorrect.

C.

The cable between the application server and the storage device is loose.

D.

The IP address of the service network port on the application server is incorrectly set.

If Huawei scale-out storage software is installed in low level design (LLD) mode, engineers need to use the ________ installation and deployment tool to plan nodes, networks, and clusters and export the configuration file for subsequent installation and deployment.

When delivering a scale-out storage project, Huawei engineers introduced the OceanStor Pacific parallel file system service to the customer. Which of the following statements is false about the service?

A.

Small I/Os are aggregated in the cache and then written to disks, achieving an ideal latency and improving the utilization of small files.

B.

Fixed-length large-granularity indexes are used to ensure sequential read/write performance of large I/Os.

C.

Large I/Os can be directly forwarded to the home node for processing, eliminating the overhead of scale-out locks and greatly reducing the read/write latency of large I/Os.

D.

In terms of I/O flow, large I/Os are written to disks in passthrough mode, improving the bandwidth capability.

An engineer wants to configure the iSCSI block service on a Huawei scale-out storage device. Which of the following operations must be performed by the engineer?

A.

Create a block storage pool.

B.

Configure the iSCSI service.

C.

Configure DPC share access on a client.

D.

Install DPC.

An engineer can use the ______ tool to install software for Huawei storage systems. This tool can collect and evaluate storage compatibility information in one-stop mode and supports batch installation of the UltraPath software, improving the software installation efficiency.

When delivering Huawei all-flash projects, Huawei engineers introduced the HyperCDP feature of flash storage to customers. Which of the following statements are true about this feature?

A.

Copies created using HyperCDP can be used for data analysis and application testing.

B.

When an application server sends a request to write data to the source LUN after a HyperCDP snapshot is created, the storage system uses the copy-on-write (COW) technology to save the new data to a new location in the storage pool and directs the source LUN’s pointer to the new location.

C.

HyperCDP snapshots cannot be directly mapped to hosts. To read data from a HyperCDP snapshot due to actual service requirements, the administrator needs to share the file system with the host so that the host can read the source file system data at the point in time when the HyperCDP snapshot was created.

D.

HyperCDP is a high-density snapshot and requires the system to construct file system objects. Therefore, the system memory usage is high.

Page: 2 / 2
Total 125 questions