Prepare effectively for your International Code Council Fire-Inspector-II 67 - Fire Inspector II Exam certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2025, ensuring you have the most current resources to build confidence and succeed on your first attempt.
Total 87 questions
The minimum fire-flow for a 3,700-sq. ft. two-family dwelling of Type VB construction with a sprinkler system is ___ GPM.
Clearance between tops of piles of combustible fibers and sprinkler heads shall not be less than ___ ft.
Flammable medical gas supply cylinders located inside of a building must be stored in a separate room of not less than __ fire-resistive construction when exceeding 200 cu. ft.
The occupant load of an R-2 building's common patio area is to be calculated using the value:
Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.
How long must records related to this decision be maintained by the code official?
Exit signs shall have words on the sign in letters ___ inches in height.
Extra-high-rack combustible storage is defined in the fire code as any storage on racks of Class I, II, III, or IV commodities which exceed ___ ft. in height, and any storage on racks of high-hazard commodities which exceed ___ ft. in height.
Given: A health club contains a 1,000-sq. ft. exercise room.
Based on the square footage, what is the calculated occupant load allowed for this exercise room?
Blocks or piles of baled fiber shall be separated from adjacent storage by aisles which are not less than __ ft wide
Multiple smoke alarms installed within individual guest rooms of a hotel must comply with which of the following requirements?
One or more approved fire extinguishers must be located within __ ft. of hot work locations.
Use, dispensing, and mixing of flammable liquids in open systems shall have continuous mechanical ventilation at a minimum rate of ___ CFM per sq. ft. of floor area.
For Halon 1211 hand-hose-line systems, all hoses for high-pressure systems must be tested at __ psi
Given: A nonsprinklered commercial Type II-B building has a fire flow requirement of 7,000 gpm. If a sprinkler system is installed throughout the building, the new required fire flow is at least ___ gpm. (Assume that the new required fire flow is sufficient to meet the requirements of the sprinkler system.)
Horizontal exits shall not comprise more than ___ of the required exits from any floor area in a Group I-2 occupancy.
A bowling center with 25 lanes and 3,500 sq. ft. of additional area calculates to a maximum occupant load of how many people?
An acceptance test for a fire alarm system in a new apartment building should be scheduled after:
A 501 gal. water capacity above-ground liquefied petroleum gas (LP-gas) tank located 20 ft. from a 250 gal. LP-gas tank must be separated a minimum of __ ft. from adjoining property.
Churches, schools, apartment dwellings, and mercantile structures are commonly built using what type of construction?
The maximum combined quantity of Class II and III liquids which may be stored in a flammable liquids storage cabinet is __ gallons.