830-01 Riverbed RCPE Certified Professional WAN Optimization Free Practice Exam Questions (2025 Updated)
Prepare effectively for your Riverbed 830-01 RCPE Certified Professional WAN Optimization certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2025, ensuring you have the most current resources to build confidence and succeed on your first attempt.
In the exhibit,
Client41 and Client42 have full access to the HTTP and FTP services provided by Server31 and Server32 respectively. They continue to have access to these servers after SH3 and SH4 are deployed. A quick check on SH3 and SH4 registers the connections from Client41 and Client 42 as pass-through traffic. Note that SH3 and SH4 are in auto-discovery mode. What are the likely causes? (Select 2)
You have an existing Steelhead appliance deployment which is achieving excellent optimization at five sites. You have deployed a Steelhead appliance physically in-path at a new small branch office and many of the new branch office users' applications are unoptimized; however some of the new branch office users' access to the same applications are optimized. None of the Steelhead appliances are in admission control. What is the likely cause?
The alerting threshold for CPU utilization is 70% and the reset threshold is 50%. Which of the following situations will result in an alarm being triggered? (Select 2)
A customer with a new physical in-path installation decides to turn on the optimization service during lunch time on a working day. This is done so that he can see if the users perceive any performance improvement. When starting the optimization service, he does not enable the in-path kickoff option. Assuming there were several already active connections when he starts the optimization service, how will the Steelhead appliances handle these existing connections?
After deploying the Steelhead appliances in-path, you are not seeing any optimization between 10.11.0.128 and 10.11.23.18.
Look at the following trace in the exhibit and explain why: (HINT: Look at the SYN packet)
Which user roles and permissions are supported by the CMC appliance? (Select 3)
What parameters are required to add a new Steelhead appliance on the CMC appliance? (Select 2)
How many versions of CMC appliance software images can reside on the CMC simultaneously?
What are the default port labels on an Interceptor appliance?
When manually registering a Steelhead appliance on the Central Management Console (CMC) appliance:
Refer to the exhibit.
A connection times out when Client41 and Client42 attempt to either establish an HTTP session to Server31 or an FTP connection to Server32 after not connecting to them for some time. The very next attempt to connect to these services done immediately after the failure seems to work correctly. The clients are able to ping both servers and no access-lists are configured on the routers. SH3 uses the IP address of R3f0 as its default gateway. Upon powering off SH3 and SH4, the problem goes away even for first connection and everything works normally (even after not connecting for extended periods of time). Which of the following are likely to correct this problem?
What interface on the CMC appliance is required for the initial configuration?
Refer to the exhibit.
SH3 and SH4 are able to optimize HTTP sessions from Client41 to application host Server31. However, Client41 receives a failure messagE. “ftp connect: Unknown error number” while trying to connect Server32. The same applies to Client42. Note that SH3 and SH4 are in auto-discovery mode. Client41 and Client42 are able to ping Server32. What is the most likely cause of this failure?
What Steelhead appliance models support the installation of Microsoft Windows Server 2008 R2 package on the RSP? (Select 2)
Refer to the exhibit.
In the accompanying exhibit, SH3 and SH4 are able to optimize FTP and HTTP sessions between Client41 and the respective application hosts Server31 and Server32. However, optimization does not happen for Client42 and these application hosts. A quick check on SH3 and SH4 registers neither optimized nor pass-through traffic from Client42. Client42 is able to ping Client41 and the in-path address of SH4. Note that SH3 and SH4 are in auto-discovery mode. What is the likely cause?
What are the methods to upload an RSP package? (Select 3)
You need to perform a tcpdump of traffic entering the Steelhead appliance's lan0_0 interface. Which of the following demonstrate the proper command format to perform the tcpdump and capture to a file?
Refer to the HTTP trace exhibit.
You noticed in the HTTP reports that you are not seeing any hits. What is required in order for HTTP optimization to work?
Which of the following is true about fetching Steelhead appliance's configurations from a CMC appliance?
Refer to the exhibit.
SH3 and SH4 are able to optimize FTP and HTTP sessions between Client41 and the respective application hosts Server31 and Server32. However, optimization seems to be a problem for Client42 and these application hosts. A quick check on SH3 and SH4 registers neither optimized nor pass-through traffic from Client42. Client42 is able to ping to both Server31 and Server32. Note that SH3 and SH4 are in auto-discovery mode. What is the likely cause?