H19-371_V1.0 Huawei HCS-Pre-sales-Digital Power V1.0 Free Practice Exam Questions (2025 Updated)
Prepare effectively for your Huawei H19-371_V1.0 HCS-Pre-sales-Digital Power V1.0 certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2025, ensuring you have the most current resources to build confidence and succeed on your first attempt.
The cooling capacity of intelligent temperature control products can only be determined when the working conditions are clarified. There are many factors that affect the cooling capacity. For example, when selecting a row-level chilled water intelligent temperature control
product, at least information such as ( ) must be specified.
Fusion Module500&Fusion Module800 - - Reasons for the typical configuration scheme recommended to customers ().
Which of the following models has the widest input voltage range and is more suitable for harsh power grids? (
Which of the following statements about wet film humidification is correct? ( ).
Compared with the fixed frequency structure, the advantages of using the DC frequency conversion structure for air-cooled temperature control products are ( )
Regarding the adjustable battery of UPS5000-E, when one of the batteries is broken, at least one ( ) battery needs to be removed. Then set the corresponding number of battery cells on the monitoring panel.
Compared with high-frequency machines, industrial frequency machines may bring more additional investment, including: ()
Regarding the characteristics of the FusionModule2000 row-level air conditioner, which of the following descriptions is wrong? ( )
FM800 video storage time ( ). .
What are the three-in-one access control methods of Fusionmodule2000 ( )
Regarding the selection of the outdoor unit of NetCol5000, what conditions should be considered ( ).
Regarding the Fusionlodule2000 wiring, which of the following statements is wrong?
The DC cable voltage drop needs to be controlled within ( ). ()
Regarding the overload capacity of UPS5000-E, which of the following statements is correct?
What are the certifications of FusionModule500&FusionModule800? (
According to the ICT Research 2018 statistical report, the market share of Huawei's line-level temperature control products in China in 2017 is: ()
The NetEco6000 management system can provide monitoring of the cooling power system, and which of the following functions can be provided? (
What are the fire-fighting linkage functions of FusionModule2000?
Which of the following are the working modes of UPS2000-A-(1K-10K)? () (multiple choice)
The difference between traditional power frequency machine and high frequency machine is ().,
Huawei Technologies Co., Ltd. is GB50174-2008 standard () is GB50174-2017 standard /
In the air-conditioning system, the correct statement of the flow direction of the refrigerant is (). In this agenda, Binleng has undergone a process of changing from high pressure gas state, high pressure liquid state, low pressure liquid state,
and low pressure gas state. ()
What are the i3 features of FusionModule2000 V3.0 version? ( )
Which of the following is true about the micro-module and fire protection system? ()
What is true about the circuit breaker statement :/
When the single cell voltage in the battery pack reaches ( ), it means that the battery pack is already in a state of risk. /
The total current of the battery pack is 1000A, and 3 sets of batteries are configured. The most economical configuration of the cable from the UPS to the main switch box is .(
Which of the following functions does the PDU8000 precision power distribution cabinet have: (multiple choice)
When multiple FusionModule products are used in the same project, when configuring NetEco, the associated application scenario should be selected ()
In UPS, corresponding to 50k modules, the maximum output capacity of a single UPS is