Prepare effectively for your Huawei H19-371_V1.0 HCS-Pre-sales-Digital Power V1.0 certification with our extensive collection of free, high-quality practice questions. Each question is designed to mirror the actual exam format and objectives, complete with comprehensive answers and detailed explanations. Our materials are regularly updated for 2025, ensuring you have the most current resources to build confidence and succeed on your first attempt.
Huawei precision air conditioners have power over-voltage, under-voltage alarm and fault diagnosis alarm record functions, automatic protection, automatic recovery, automatic restart and other functions.
The communication between NetEco management system and ECC800 collector adopts Huawei's proprietary protocol BIN protocol.
PDU8000 precision power distribution cabinet supports monitoring of branch circuit phase current, active power, electric energy and branch circuit switch status.
In the UPS5000 configuration, the power supply reliability level can not be selected
In Fusionmodule2000, the linkage between the indoor and outdoor units of the air conditioner can control the speed of the fan and the speed of the compressor to reduce the power consumption of a single unit ()
Each jack of rPDU in FM2000 supports independent switch ( ).
FusionModule800 can only support lower pipe ()
The four remotes mentioned in the monitoring system refer to telemetry, remote signaling, remote adjustment, and remote control, and the corresponding monitoring signals are AI and DI. AO. DO these four signal types.
The control sunroof of Fusionmodule2000 cannot be flipped open ( )
ECC800 data room controller does not support log export ( )
When configuring the cables of the UPS, it is necessary to consider the rated current of the UPS and the voltage drop on the line for selection.
AHU can be stacked or installed on the roof, flexible deployment ( )
UPS5000-E (50kVA module) supports the adjustable number of battery cells to avoid the replacement of a whole battery caused by a single battery failure and solve the problem of difficult maintenance of
traditional UPS batteries. The adjustable range is 30~44 cells ( ).
Which manufacturers have 50KVA power modules
Fusion Module2000 requires a minimum floor height of 2.6 meters ( ).
Huawei network management NetEco supports northbound SNMP protocol ( )
Huawei Neteco network management supports mobile APP management
The UPS5000-E battery adopts the design of no neutral line, which is convenient for the battery to be used when replacing the tower.
The UPS5000-A control unit adopts a 1+1 redundancy design. When any control unit fails, it can smoothly switch to another control unit, which can effectively prevent the occurrence of single-point failure of the
control system and improve the reliability of power supply of the system.
The self-developed air-conditioning control system has a visual group control network and supports a maximum of 32 units
Are the Fusion Module500&Fusion Module800 air conditioners connected to the back end of the UPS? ( ).
FusionModule supports access control by swiping card, but does not support two-way card swiping. ( ). /
The UPS5000-S power module has a capacity of 50kVA and a height of 2U, the highest power density in the industry.
The intelligent rPDU in Huawei FM2000 only supports C19 and C13 specifications ().
FusionModule1000A V2R3 version 20-foot CT solution is equipped with 4 600*800*2200mm CT cabinets
The bypass module of UPS5000-E-200K (50kVA power module) is the same as that of UPS5000-E-300K ( )
The integrated UPS rack frame is available in 50Kva and 125Kva ( ).
UPS can be placed outside Fusionmodule2000 ( )
Huawei Netcol air-cooled air conditioner requires low temperature components when the outdoor temperature is lower than -20"C ()
FusionModule2000 integrated UPS has two types of 50K/125K.